bpdu-flood-enable
Configures the MCT cluster devices to flood the SSTP or MSTP BPDUs in the SSTPor MSTP domain.
Syntax
bpdu-flood-enable
no bpdu-flood-enable
Command Default
BPDU flooding is not enabled.
Modes
Global configuration mode
Usage Guidelines
When bpdu-flood-enable is configured, there should not be any links other than the ICL connecting the two MCT cluster devices. If there is an additional link, then the flooded BPDU will cause a loop and high CPU utilization.
NOTE
The
bpdu-flood-enable command is not supported on the Brocade ICX 7750.
The no form of the command disables the BPDU flooding.
Examples
The following example shows how to configure BPDU flooding on the device.
device(config)# bpdu-flood-enable Warning - Any recieved untagged BPDUs will now be flooded to all the ports.