Configuration notes for traditional stack mirroring

The following mirroring configuration information applies to FastIron devices connected in a traditional stack topology:

  • The input or output mirroring port can be on different ports.
  • All FastIron devices can have one mirroring port that monitors multiple ports, but cannot have multiple mirror ports for one monitored port.
  • If the mirror port and the monitored ports are on different stack units, only one active mirror port is allowed for the entire traditional stack.
  • If the mirror port and the monitored ports are on the same port region, multiple active mirror ports are allowed for the entire traditional stack. Devices in a traditional stack support 24 ports per port region.
  • The maximum number of monitored VLANs on a traditional stack is 8.