Displaying the device information

To display the device information, perform the following steps.

  1. Click Monitor on the left pane and select Device.
  2. For the Brocade FCX and Brocade ICX devices, select a stack Identifier from the Stack Unit ID list and click Display to view the information for any device in an IronStack.
    NOTE
    The Stack Unit ID list is not available in the Device Information window for the Brocade FastIron SX devices.

    The Device Information window for the Brocade FCX and Brocade ICX devices is displayed as shown in the figure below.

    Figure 7  Monitoring the device information
    Table 3 Description of the fields in the Device Information window

    Field

    Description

    Stack Unit ID

    Displays the number of the unit within a stack.

    NOTE
    This field is not available in the Device Information window for the Brocade FastIron SX devices.

    Role

    Displays the role of the device, which can be Active, Standby, Member, or alone. If the role is alone, the device is operating as a standalone device.

    NOTE
    This field is not available in the Device Information window for the Brocade FastIron SX devices.

    System Up Time

    Displays the quantity of time the system has been running since the last restart.

    System Started At

    Displays the time when the system started.

    System Clock

    Displays the time configured in the system.

    Running Image Version

    Displays the software version currently running and some details on the version.

    Flash Primary Image Version

    Displays the release number and size of the software loaded on the primary flash.

    Flash Secondary Image Version

    Displays the release number and size of the software loaded on the secondary flash.

    Boot Image Version

    Displays the release number and size of the boot image.

    Temperature

    For the Brocade FCX and Brocade ICX devices, this field displays the actual temperature. The color of the degrees provides a visual indicator for the device:

    • Green—The temperature is within the normal operating range.
    • Orange—The temperature has reached the warning level.
    • Red—The temperature has reached the shutdown level.

    For the Brocade FastIron SX devices, click Temperature in the right pane to display the Chassis Temperature Information window, which shows the temperature of each slot (from 1 through 10) and the switch fabric modules SF 1 and SF 2. Figure 8 shows the Chassis Temperature Information window.

    Warning temperature

    Displays the warning level temperature.

    NOTE
    This field is not available in the Device Information window for the Brocade FastIron SX devices.

    Shutdown temperature

    Displays the shutdown level temperature.

    NOTE
    This field is not available in the Device Information window for the Brocade FastIron SX devices.

    CPU Utilization

    Displays the percentage of CPU being used by the device at 1-second, 5-second, 1-minute, and 5-minute intervals.

    Serial Number

    Displays the serial number of the device.

    License

    Displays the software license and License ID (LID) of the device.

    NOTE
    This field is not available in the Device Information window for the Brocade FastIron SX devices.

    Power Supply 1

    Displays the status of the primary power supply.

    Power Supply 2

    Displays the status of the secondary power supply, if present.

    Fan 1

    Displays the status of the primary cooling fan.

    Fan 2

    Displays the status of the secondary cooling fan, if present.

    NOTE
    There is an entry for each fan in the device.

    The figure below shows the Chassis Temperature Information window for the Brocade FastIron SX devices.

    Figure 8  Monitoring the chassis temperature